1997-11:2 © Scania Industrial & Marine Engines 13
MAINTENANCE SCHEDULE
1. More often if required
2. For engines with few operating hours, see page 12.
3. Earlier if low pressure indicator shows red.
4. If inhibitor has not been topped up for five years, coolant should be changed.
Daily
First
time at
Interval At least
At first start
400 h
200 h
400 h
1200 h
2400 h
4800 h
Every year
Every 5th year
LUBRICATION OIL SYSTEM, page 14
1. Checking oil level
l l
2. Oil change
l1 l
3. Cleaning the lubrication oil cleaner
l1 l
4. Changing the turbo filter
l1 l
COOLING SYSTEM, page 18
5. Checking coolant level
l
6. Checking coolant
l l4 l
7. Cleaning cooling system
l1 l
AIR CLEANER, page 24
8. Test reading low pressure indicator
l
9. Cleaning coarse cleaner
l1 l
10. Cleaning or changing filter insert
l3 l
11. Changing safety cartridge
l l
FUEL SYSTEM, page 26
12. Checking fuel level
l l
13. Changing main filter
l1 l
14. Checking injectors
l l
ELECTRICAL SYSTEM, page 28
15. Checking electrolyte level in batteries
l l2 l
16. Checking charge state of batteries
l l2 l
17. Cleaning batteries
l2 l
18. Checking level monitor
l l l
19. Checking temperature monitor
l l l
20. Checking oil pressure monitor
l l l
21. Checking stop function
l l l
MISCELLANEOUS, page 33
22. Checking v-belts
l l l
23. Look for leakage. Remedy as necessary
l
24. Checking/adjusting valve clearance
l l
25. Changing (or cleaning) valve for closed crankcase
ventilation
l