EasyManua.ls Logo

Scania DC13 XPI - Reaction to Low Reductant Level; Reaction to Fault in SCR System

Scania DC13 XPI
117 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Starting and running
OPM 200 en-GB 28
© Scania CV AB 2020, Sweden
Reaction at low reductant level – Stage
IIIB/IV/Tier 4i/Tier 4f
The engine resumes normal torque after reduct-
ant has been filled to a level of at least 20%.
Reaction at low reductant level – Stage V
Note:
Its behaviour and the symbol depend on the in-
stallation of the engine in the machine. The Sca-
nia recommendation will lead to the behaviour
and symbol described here, but this may differ
between different machines.
The engine resumes normal torque after reduct-
ant has been filled to a level of at least 20%.
Reaction to fault in SCR system – Stage
IIIB/IV/Tier 4i/Tier 4f
Reductant
level
Warning
lamp
Torque reduction
1
1. Applies only to engines certified according to Tier 4.
20% Constant
light
10% Flashing Torque is reduced by
1% per minute to
70 % of the highest
torque.
0% Flashing rap-
idly
Torque is reduced to
0% (low idling)
within 2-10 minutes.
Level Warning lamp Torque and
speed control
20% Constant light -
10% Flashes slowly
Hz)
Torque is reduced
by 1% per minute
to 75 % of the
highest torque.
0% Flashes rapidly
(2 Hz)
Torque is reduced
by 1% per minute
to 50% of the
highest torque.
The engine speed
is reduced to 60%
of the nominal en-
gine speed.
319 562
Symbol for low reductant level.
319 562
Symbol for low reductant level.
319 563
Symbol for fault in SCR system.

Table of Contents