3.
Check drive belt wear. Renew the drive belt
if it is too worn.
Checking for leakage
IMPORTANT!
If serious leakage occurs, contact your nearest
workshop.
1. Start the engine.
2. Check for oil, coolant, fuel, air or exhaust
leakage.
3. Tighten or renew leaking connections.
Check the overflow holes which show
whether the O-rings between the cylinder
liners and crankcase are leaking.
4. Check whether the drain hole on the coolant
pump is blocked. If there is leakage, renew
the seal in the pump or the complete coolant
pump assembly.
The drive belt is starting to become worn, but can be
refitted.
The belt is worn down to the cord. The drive belt
must be renewed.
112 931
112 932