Action when a fault arises
LED indications in the event of a fault
Note: It is indicated on the main indicator lamp in
the main supply box and on the instrument
panel. The lamp test/fault code switch should
not be depressed.
CONTROL STATUS
< The LED continues to flash even if a fault has
occurred as long as the control unit is powered
up.
POWER-
< If the LED comes on, the control unit has
detected a fault condition which could result in
engine damage if allowed to continue.
The control unit automatically reduces the
power to a special level if this function has
been selected.
Action: If possible reduce engine speed to idle
and conduct troubleshooting according to
instructions on page 17 and the chart on
page 18.
SHUTDOWN
< The LED comes on and the engine is switched
off automatically in the event of a fault so
serious that the engine could be damaged if it is
still in operation.
Action: Conduct troubleshooting according to
instructions on page 17 and the chart on
page 18.
If the engine has not stopped, reduce engine
speed to idle and carry out troubleshooting.