2003-10:1 © Scania Industrial & Marine Engines 43
18. Every 1200 hours:
CHECKING THE COOLANT MONITOR
(optional equipment)
1. Start the engine.
2. Lower the coolant level in the expansion tank.
3. Automatic stop in case of fault: Engine stops, indicator lamp is on, and
buzzer sounds if there is no fault in the level monitor.
4. No automatic stop in case of fault: Indicator lamp is on, buzzer sounds
if there is no fault in the level monitor.
5. Top up coolant to the correct level, see page 32.
2-pin level monitor installed in the
expansion tank for radiators
supplied by Scania
Use a container to avoid spillage
when draining the coolant.
Dispose of used coolant through
an authorised waste disposal
contractor.