50 © Scania Industrial & Marine Engines 2003-10:1
24. Every 2400 hours:
CHANGING (or CLEANING) THE
CLOSED CRANKCASE VENTILATION
VA LV E
Alternative 1:
Change the valve at the specified interval.
Alternative 2:
- Remove the valve after the specified interval.
- Clean the valve by placing it in a bath of diesel fuel oil overnight.
Then rinse it several times in diesel and allow it to drip dry.
- Refit the valve.
- The valve may be reused (cleaned), but not more than twice after the
first 2400 hours of use. Take care to mark the valve after cleaning it.