Cooling system
OPM 360 en-GB 41
© Scania CV AB 2017, Sweden
Renewing the sea water pump impel-
ler
Special tool
Note:
If the impeller must be renewed frequently, the
cleaning of the sea water needs to be improved.
There should be a spare impeller on board.
The impeller can be deformed during extended
periods of inactivity. Renew the impeller before
starting or remove the impeller before longer pe-
riods of stoppage.
1. Thread the puller stud into the rubber impel-
ler using an internal hexagon key until the
stud reaches the bottom.
Note:
Note the direction of rotation of the impeller
vanes.
2. Screw the puller into the rubber impeller us-
ing the handle until it reaches the stud. Then
continue to screw until the impeller comes
loose.
3. Unscrew the stud.
IMPORTANT!
Check that the direction of rotation of the impel-
ler vanes is the same as during removal.
4. Lubricate the impeller with pump grease and
then fit it using a rubber mallet.
5. Fit the sea water pump cover. Tightening
torque 7.5 Nm (5.5 lb/ft).
Number Designation Illustration
2 443 680 Puller
361 638
361 639
Sea water pump cover.