5.6 Trouble shooting
5.5.1 Common faults
Symptom Cause Correction A
The machine won’t start There is a power failure from the power sup-
ply
Inspect the fuses in the worksites fuse box
Inspect cables
Measure that all three phases are present and at full
voltage near the machine
O
E
E
The emergency stop button is depressed Release the emergency stop button. O
Internal error If possible, read the alarm or fault code present at the
display inside of the electrical cabinet. Alarm codes are
formatted as “Axxxx” where “x” is the number. Fault
codes are formatted as “Fxxxx”.
Contact Scanmaskin Sweden AB
O
The machine is weak and
might stop when on the
ground.
One of the three phases are missing from the
power supply
There is a voltage drop at the power supply
Inspect the display on the inverter for any alarm code
Inspect the fuses in the worksites fuse box
Inspect cables
Measure that all three phases are present and at full
voltage at the cable end near the machine.
Make sure that the cable is not to long. If the cable
should be to long, use a cable with higher rating to a
distribution box nearer the machine.
O
O
E
E
O
The machine vibrates a lot The grinding speed is to high Lower the speed O
The tools are damaged Inspect the tools
Change the tools if needed
O
O
Table 5.1Common faults