9.3 Table / diagnosics data
9.3.3 Position 3 - Digital input status
9.3.4 Position 4 - Error code log
9.3.4.1 Clear error code log
Press On-button three times from position D:i – 0:0
D:i–0:3isdisplayedfor1second,theLED-displaywillthentoggleallCentralUnitdigitalinputs
and present current value (High or Low).
i:n – 0:1 - 0:1 or 0:0 (High/Low)
i:n – 0:2 - 0:1 or 0:0 (High/Low)
i:n – 0:3 - 0:1 or 0:0 (High/Low)
i:n – 0:4 - 0:1 or 0:0 (High/Low)
As to determine the current status for all digital inputs.
WhileinthispositiontheLED-displaywillpresenteachdigitalinputfrom1to4,highorlow,con-
tinuously
Press On-button four times from position D:i – 0:0
D:i–0:4isdisplayedfor1second,theLED-displaywillthentogglethe5mostrecenterrorcodes
that have been triggered in the Central Unit.
AstodeterminefaultsregisteredbytheCentralUnit,refertochapter7forerrorcodeinformation.
The LED-display will toggle the logged error codes continuously.
Hold Micro-toggle in LEFT position for 5 seconds
E:r – C:L is displayed in the LED-display (Error Clear)
ReleaseandpressMicro-toggleoncemoretoLEFTpositiontoconrm.
Central Unit error code logg is cleared.
An error code clear is suitable to conduct after service!
9.3.2 Position 2 - Digital output status
Press On-button two times from position D:i – 0:0
D:i–0:2isdisplayedfor1second,theLED-displaywillthentoggleallCentralUnitdigitaloutputs
and present current value (High or Low)
O:n – 0:1 - 0:1 or 0:0 (High/Low)
O:n – 0:2 - 0:1 or 0:0 (High/Low)
O:n – 0:3 - 0:1 or 0:0 (High/Low)
…
O:n – 1:4 = 0:1 or 0:0 (High/Low)
As to determine the current status for all digital outputs.
WhileinthispositiontheLEDdisplaywillpresenteachdigitaloutputfrom1to14,highorlow,
continuously
Document type Document number PageRev
Service Manual S071 C