4 MOUNTING AND INSTALLATION COD.150M230.T.2021
EN
THE PRESENT MANUAL BELONGS TO - Schenker Italia - ALL RIGHTS RESERVED
26
ATTENTION
The use of an improper hose can cause a break which prevent the security of the vessel.
WATERMAKER CONNECTIONS:
WATERMAKER INLET (Sea water inlet from the pump):
Make use of the external holder located on the left side of the watermaker (marked IN).
WATERMAKER OUTLET (Discharge outboard):
Make use, for this connection, of the holder located on top of the pressure amplifier, inside the watermaker
unit (marked OUT). Create a Swan neck upward, when the drain outlet on the vessel is positioned below the
watermaker unit, in order to guarantee a water head.
PRODUCTION FRESH WATER CONNECTION
The connection has to be made using the small hose
supplied with the equipment. The connection has to be
made between the polyethylene hose that comes out
the watermaker unit (on the right), and the upper side
of the tank, on a ¼” outlet if available.
It is possible, in case of metal tanks, to make a ¼”
threaded hole to connect the supplied male connector.
Another option is to Tee into the tank air vent
hose.There are no particular limits on the connection
length.