L Service Manual
10
Lock Assembly Drawing Index
Functions
ANSI A156.13, 1994 Series 1000
Trim
Assembly
Page Number
Lock
Assembly
Page Number
Lock Case
Part Number
Keyed Locks
SCHLAGE ANSI
L9464 x XL11-886 Single Cylinder Deadbolt with Retraction by Inside
Knob/Lever
Deadbolt is operated by key outside. Rotating inside knob/lever
retracts deadbolt. Outside knob/lever is always fixed.
Specify per XL11-886.
24 78
L9465 Closet/Storeroom Lock
Latchbolt is operated by knob/lever from either side. Deadbolt is
operated by key outside.
24 79 L283-140
L9466 F14 Storeroom/Utility Room Lock*
Latchbolt is operated by knob/lever from either side. Deadbolt is
operated by key from either side.
23 79 L283-140
L9473 F21 Dormitory/Bedroom Lock
Latchbolt is operated by knob/lever from either side. Deadbolt is
operated by key outside or turn piece inside.
22 79 L283-140
L9480 Storeroom Lock with Deadbolt
Latchbolt is operated by key outside or by knob/lever inside.
Outside knob/lever is always fixed. Deadbolt is operated by key
outside or turn piece inside. Turning inside knob/lever
simultaneously retracts both deadbolt and latchbolt. Auxiliary
latch deadlocks latchbolt when door is closed. Inside knob/lever
is always free for immediate exit. (Previously XL11-591)
31 80 L283-141
LV9480
Storeroom Lock with Deadbolt with Vandlgard
®
Latchbolt is operated by key outside or by knob/lever inside.
Outside knob/lever is always inoperativef. Deadbolt is operated
by key outside or turn piece inside. Turning inside knob/lever
simultaneously retracts both deadbolt and latchbolt. Auxiliary
latch deadlocks latchbolt when door is closed. Inside knob/lever
is always free for immediate exit. Vandlgard function allows
exterior lever to rotate freely down while remaining securely
locked. (Previously XL11-591)
31 81 L283-178
* CAUTION: Double cylinder locks on residences—or on any door in any structure which are used for egress—are a life safety hazard in times of
emergency, and their use is not recommended. Installation should be in accordance with existing codes only.
Not sold separately as a part.