Assembly
04.01|MPG-plus |en
29
For grippers in this size a special fastener has to be used (please
contact SCHUNK service hotline)
The already mounted standard fastener can not be used.
Fig. 21
1 Remove the standard fastener from the sensor.
2 Mount the special fastener instead of the standard fastener.
However do not fix the mounting screws of the fastener com-
pletely.
3 Push the sensor into the fastener until it bears against the in-
ternal stop of the fastener.
4 Firmly tighten the mounting screw of the fastener.
5 Turn the mounting screw on the sensor to the right (clockwise)
using an Allen key to fix the sensor in place.
1 Push the magnetic switch into the holder until it comes into
contact with the internal back stop for the holder.