Maintenance and lubrication intervals
NOTICE
At ambient temperature above 60°C the lubricants can
harden faster.
Interval decrease accordingly.
Maintenance interval
MPG-plus
16 - 20 25 - 32 40 - 50 64
Interval [Mio. cycles] 15 5 4 3
Lubricants/Lubrication points
We recommend the lubricants listed.
During maintenance, treat all greased areas with lubricant. Thinly
apply lubricant with a lint-free cloth.
Lubricant point Lubricant
Metallic sliding surfaces microGLEIT GP 360
All seals Renolit HLT 2
Bores on the piston Renolit HLT 2
In addition to the described maintenance, the guides of the gripper
can be re-lubricated as needed by means of lubricating nipples.