Assembly
38
10.00 | SWS 005 – 300 | Assembly and Operating Manual | en | 389456
Ø Dock the Tool safely in the tool stand and uncouple the Tool
Changer to allow clear access to the SWK or SWA.
Ø Turn off all energized circuits (e.g. electrical, air, water, etc.).
Ø Disconnect any cables, if required.
Ø Remove the two screw locks securing the connector to the
module.
Ø Carefully remove the connector to expose the mounting screws.
Ø Support the module, while removing the two M3 socket head
cap screws holding the module to the SWA.
Ø Remove the module from the SWA.
5.9.5 Flat A Optional K Series Module Installation - SWS-020 and
SWS-021
SWK
(SWK-021 shown)
M3 Socket Head
Cap Screws (2x)
Electrical Module
(SWO-K19-K
shown)
M3 Socket Head
Cap Screws (2x)
Electrical Module
(9SWO-K19-A shown)
SWA
(SWA-021 shown)
Ø Align optional module on flat A of SWK or SWA.
Ø Apply Loctite 222® to M3 socket head cap screws.
Ø Secure module with two M3 socket head cap screws. Tighten to
0.8-1.2 Nm.
Ø Remove all protective caps, plugs, tape, etc from the module
prior to operation.