Maintenance and Care
10.00 | SWS 005 – 300 | Assembly and Operating Manual | en | 389456
55
Ø Insert the Lock and/or Unlock sensor into the Tool Changer
body.
Ø Secure the sensor assembly using the two M3 socket flat head
screws. Tighten to 1.4 Nm.
Ø Connect the Lock and/or Unlock sensor cable connector to the
proper sensor.
Ø Confirm the operation of the Unlock sensor by issuing the
Unlock command.
✓ Check to see that the LED in the Unlock sensor body is on.
Ø Confirm the operation of the Lock sensor by issuing the Lock
command to lock a SWA to the SWK .
✓ Check to see that the LED in the Lock Sensor body is on.
8.5 Rubber Bushings
Rubber Bushing Replacement
NOTE
Collars only needed for sealings size G 3/8" and G 1/2".
If one or more pneumatic pass-through rubber bushings should
become cut or damaged in such a way that the seal when coupled
is hindered, the bushing(s) require replacement.
For models with small ports (G 1/8" and M5):
Ø Remove damaged rubber bushing by grasping with a pair of
needle-nosed pliers and pulling the bushing out of the body.
Ø Dip new bushing in water to aid in installation.
Ø Insert the beveled (chamfered) end of the rubber bushing into
the bore, leaving ribbed end of the bushing facing outward.