Maintenance and Care
50
10.00 | SWS 005 – 300 | Assembly and Operating Manual | en | 389456
Ø To test the suspect sensor, place a ferrous target in front of the
Proximity Sensor to confirm that the sensor is functional. The
sensor lock or unlock signal should read “on”(true) and the
sensor LED should illuminate.
Sensor Interface Plate (SIP)
Detection Shaft
M3 Socket Set Screw
Proximity Sensor
SWS-011
SWK
(4x) M3 Socket Head Cap Screws
Ø If the proximity sensor is not functioning properly replace.
Disconnect the sensor cable and discard.
Ø Thread the proximity sensor into the SWK-011 until it touches
the Detection Shaft, then back the sensor off 1/2 turn.
Ø Connect the sensor cable. The Proximity Sensor LED should be
illuminated.
NOTICE
Operating the locking mechanism with the sensor touching the
detection shaft will damage the sensor.
Do not operate locking mechanism with sensor touching the
detection shaft.
Back off the sensor ½ turn and secure with the set screw
before operating the locking mechanism.
Ø Turn the M3 socket set screw until it contacts the sensor and
tighten 1/4 turn more.