FLOW-SETTING AND TEST FS-2
Note:
If escape apparatus again fails the duration and flow test, refer to the Fault-finding
Chart contained within the Product Module of this Manual and rectify accordingly. Re-
test upon completion of rectification.
WARNING:
DO NOT use escape apparatus that fails the duration and flow test.
6.
Once apparatus has passed duration and flow test, seal flow-setting screw by
applying a small amount of Loctite 542 sealant around screw head.
7.
When sealant has set, affix replacement label in position to conceal flow-setting
screw.
8.
Follow after testing instructions given in Section 4.4 of this Module.
4.4
AFTER TESTING
Once apparatus has successfully passed duration and flow test:
1.
Disconnect hood connector from port on test equipment and secure hood
connector to inlet fitting on hood using U-Clip.
2.
Locate exhale valve assembly into exhale valve fitting on hood and secure in
position with exhale valve cover.
3.
Fully-charge cylinder and prepare escape apparatus for service as described in
the Product Module of this Manual.
4.
Complete breathing apparatus log.
5.
Ensure that test equipment is clean and undamaged. Store test equipment
safely for future use.
Issue C 12. 2009
FS-2
(Page 5)