EasyManua.ls Logo

Scott Safety ELSA - Leak-Test LKT-7

Scott Safety ELSA
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LEAK-TEST LKT-7
1. TECHNICAL DESCRIPTION
The leak-test confirms that any leakage from the apparatus is within a safe and
acceptable limit. This Module details the procedure for leak-testing constant-flow
escape breathing apparatus.
2. TEST EQUIPMENT
This test requires the use of Leak-detection Fluid.
3. TEST PROCEDURE
1.
Ensure that escape apparatus is fully-charged.
2.
Use a soft brush to apply Leak-detection Fluid to connections and joints,
particularly around:
Hose port;
Reducer head;
Contents gauge;
Charging adaptor;
Cylinder neck.
3.
Pull firing pin on escape apparatus to begin constant flow of air.
4.
Inspect connections and joints for evidence of bubbles, which will indicate a
leakage of air.
5.
Rectify leakage in accordance with the Fault-finding Chart contained within the
Product Module of this Manual.
6.
Once rectification has been completed, re-test apparatus as described above.
7.
Testing is complete once no evidence of leakage is detected.
8.
Upon completion, clean Leak-detection Fluid from apparatus.
9.
Fully-charge cylinder and prepare escape apparatus for service as described in
the Product Module of this Manual.
Issue A 01. 2010
LKT-7
(Page 1)

Related product manuals