9/12 Ref. GPAO : 33522111601 Ref. Const. 5490 326 4000
8. Storing the generating set
Generating sets, which are to remain unused during a long period of time must undergo certain procedures, in
order to keep them in good condition. Check that the storage area is not dusty or humid. Clean the outside of the
generating set and apply a rustproofing product
8.1. Oil
While the motor is still hot, drain the oil from the sump and replace it with new oil of suitable quality.
8.2. Fuel
❶ Open the enclosure with a screwdriver
❷ Disconnect the spark plug cap
❸ Drain the fuel tank into a suitable container
❹ Turn the fuel tap to the "ON" position, unscrew the carburettor drainage screw, then drain off the fuel into a
suitable container
❺ Hold the recoil starter handle then pull 3 to 4 times on the handle, in order to completely drain the carburettor
❻ Turn off the fuel tap, refit the carburettor drainage screw, reconnect the spark plug cap, then, close the
enclosure again.
8.3. Spark plug
❶ Remove the spark plug, pour approximately one soup spoon of oil into the spark plug well, run the motor
several times to disperse the oil in the cylinder then refit the spark plug
9. Troubleshooting
Probable causes Remedial action
The generating set is being charged during
start-up
Take it off charge
Fuel level too low Fill up with fuel
The fuel tap is closed Open the fuel tap
Fuel supply blocked or leaking Have the system repaired
Blocked air filter Clean the air filter
The motor will not
start
Control on "О"
Switch to "I"
Probable causes Remedial action
Blocked ventilation inlets Clean the air inlet and outlet guards
The motor cuts out
overcharge probable (overcharge indicator
turned on)
Control the charge, wait 30 second and
start again
Probable causes Remedial action
Circuit breaker tripped out (direct current) Reset the circuit breaker
Faulty circuit breaker (direct current) Have it checked, repaired or replaced
Faulty plug sockets Have it checked, repaired or replaced
Faulty appliance supply lead Change the leads
No electric current
Faulty alternator Have it checked, repaired or replaced
Probable causes Remedial action
Circuit breaker trips
out
Faulty equipment or lead Have it checked, repaired or replaced