The JOLLY programmer allows to keep under control and to change all parameters of the control unit without need to use the
buttons of the control unit. Compared to the on-board display, the programmer allows to view the programming instructions in
the user's language and in a non-encrypted way. In addition to the JOLLY programmer, the user can work comfortably standing
up without looking at the control unit.
PROGRAMMER JOLLY PARAMETERS ADJUSTMENT
Screen 2
Screen 3
Motor [Barrier / Sliding doors magnet / Erg / Verg L. 3m / Verg L. 4m / Verg L. 5m]
Screen 1
Screen 4
Screen 5
Screen 6
Language: IT Available languages: IT,EN,FR,ES [ Italian, English, Spanish, French]
Speed [30÷100 ] motor 1 speed adjustment
Sp.Decel.O1 [Off÷100 ] motor 1 slowdown space in opening adjustment
Slow Speed [30÷100 ] slowdown speed adjustment
Learn speed [30÷100 ] selflearning speed adjustment
Sp.Decel.C1 [Off÷100 ] motor 1 slowdown space in closing adjusmtent
Torque op.M1 [10÷100]% (max. motors current)
SoftStart [0÷100 ] motor 2 slowdown space in closing adjustment
Torque cl.M1 [10÷100]% (max. motors current)
Cycle [Secur./auto/deadman/step1/step2/two buttons]
Pause time [0÷240]s (pausing time in seconds, 0s halfautomatic logic)
Learning Times learning [On-Off]
Cycles [0÷... ] (Number of executed cycles )
Pedestrian [30÷100]% (Pedestrian opening rate)
Anti Intrusion [Off,Open,Close.,op.cl.] (Implies the presence of a N.C. contact on
limit switch which if released forces the motors in closing)
Preblink [Close, Off, 0÷5s] (Only before closing, OFF from 0 to 5s)
Light Time [Cycle, Off, 0÷240s] (Only during cycle, OFF from 0 to 240s)
Ph.test [1,2-1-2] (Only on Foto1, only on Foto2, on both)
Max Cycles [100÷100000] (Number of cycles for maintenance)
The arrow
indicates that the
parameter can be
changed with the +
and - buttons.
Master-Slave Master-Slave mode (OFF / Slave / Master)
USER 1 - 24V DG
17
International registered trademark n. 2.777.971
67411535 REV 03 - 05/2013