51JDL V1.0 8 2022
Motor Errors
Error Message Descripon Possible Soluons
Motor [Number] Open The motor indicated or harness to
that motor has an open electrical
connecon.
Check the motor and motor harness
for open connecons. Test vend motor.
Replace if necessary.
Motor [Number] Short The motor or harness has an elec-
trical short.
Check motor and motor harness for
short. Replace if necessary.
Motor [Number] Home Sns The motor home switch was not
detected while the motor was in
operaon. This may also indicate a
motor jam condion.
Check motor type service mode seng,
motor, motor switch and then spiral for
blockage. Test vend selecon motor if
necessary.
Motor [Number] Jam A motor jam has been detected. Check motor and spiral for blockage.
Motor [Number] Errors One or more motor errors have
been detected.
Test vend selecon motor and review
informaon on motor open, short, home
switch and jam condions.
Motor Under Voltage The detected motor voltage is not
high enough to run the selecon
motors.
Test vend selecon motor for correct
operaon. Replace motor. Replace VMC.
Temperature Sensor Errors
Error Message Descripon Possible Soluons
Refrig Sensor # Open A temperature sensor or harness is
considered to have an open elec-
trical connecon. Where # is the
sensor number.
Check sensor and sensor harness for
open connecons. Check for sensor
readings. Replace sensor if necessary.
Refrig Sensor # Short A temperature sensor or harness
is considered to have an electri-
cal short. Where # is the sensor
number.
Check sensor and sensor harness for
shorted connecons. Replace if neces-
sary.
Refrig Health Safety The cabinet temperature and me
limit sengs have been exceeded.
Check sensor readings and sensor
harness for shorted connecons. Check
for sensor readings. Replace sensor if
necessary.
Vend Sensor Errors
Error Message Descripon Possible Soluons
Opcal Sensor Error Not Applicable NA