IMAG 4700r INSTRUCTIONS
Seametrics • 253.872.0284 Page 6 seametrics.com
GENERAL INFORMATION
iMAG Accuracy
Flow Rate (2” - 12”)
Pipe Size
(Inchesindiameter)
2” 3” 4” 6” 8” 10” 12”
Max Flow Rate
(Gallons/Minute)
321 722 1285 2891 5140 8031 11565
Cut-o (min) Flow
Rate
(Gallons/Minute)
2 4.0 6.43 14.46 25.70 40.15 57.82
Max Flow Rate
(Liters/Second)
20.25 46 81 182 324 507 730
Cut-o (min) Flow
Rate
(Liters/Second)
0.13 0.23 0.41 0.91 1.62 2.54 3.65
Max Flow Velocity
(Meters/Second)
10 10 10 10 10 10 10
Accuracy (%)
Flow Velocity
0
1
2
3
4
5
33 0 5 10 15 20 25 30
(m/s)
(ft/s)
0
1
2
3
4
5
5
10 15
20
25 30
33
0
420 6 8 10
AG3000
AG3000r & AG3000p
0
1
2
3
4
5
33 0 5 10 15 20 25 30
(ft/s)
5
10 15
20
25 30
33
0
Pressure Drop (PSI)
(m/s)
0 1
2
3
4
5
6
7
8
9
10
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
3 Inch Pressure Drop
2 Inch Pressure Drop
Flow Velocity
2” & 3” Pressure Drop
Note: No pressure drop in 4”-12” meters

Other manuals for Seametrics iMAG 4700r

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Seametrics iMAG 4700r and is the answer not in the manual?

Seametrics iMAG 4700r Specifications

General IconGeneral
BrandSeametrics
ModeliMAG 4700r
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals