IMAG 4700r INSTRUCTIONS
Seametrics • 253.872.0284 Page 4 seametrics.com
GENERIAL INFORMATION
Specications*
Modbus is a registered trademark of Schneider Electric.
* Specicationssubjecttochange.Pleaseconsultourwebsiteforthemostcurrentdata(www.seametrics.com).
1
Ifforwardandreverseowdataneedstobesenttoanotherdevice,Modbusoutputisrequired.
2
RateTimeUnitisavailableinDayonly.
3
Forwardandreverseowtotalsarenon-resettable.Batchforwardandbatchreversetotalscanbereset.
Pipe Sizes 2”, 3”, 4”, 6”, 8”, 10”, 12”
Flanges 150 lb. ANSI Pattern
Pressure 150 psi (10.3 bar) line pressure
Temperature Operating 10˚ to 140˚ F (-12˚ to 60˚ C)
Storage -40˚ to 158˚ F (-40˚ to 70˚ C)
Accuracy ±0.75% of reading on iMAG 4700p and 4700r (±1.0% iMAG 4700), ±0.025% of full-scale ow from low
ow cuto to maxi. ow rate of 10 m/sec
Low Flow Cuto 0.5% of maximum ow rate
Material Body (2”-12”) Welded steel, epoxy-coated
Liner (2”,3”&8”) Polyurethane/Noryl
®
Liner (4”,6”,10”&12”) Santoprene ange/Polypropylene liner body
Electronics Housing Powder-coated diecast aluminum
Electrodes 316 stainless steel standard/ Hastelloy optional
Display Type 128x64 dot-matrix LCD
Digits 5 Digit Rate 8 Digit Total
Units
PleaseNote:
AlliMAGmetersarefactory
set for gallons per minute
(GPM)rateandgallons
total. If other units are
required,theycanbesetin
theeld.
Rate Volume Units Rate Time Units Total Volume Units
Gallons
Liters
Barrels(42 gal)
Cubic Feet
Cubic Meters
Million Gallons
2
Mega Liters
2
Imperial Gallons
Million Imperial
Gallons
2
Second
Minute
Hour
Day
Gallons
Gallons x 10
Gallons x 100
Gallons x 1000
Million Gallons
Liters
Kilo Liters
Mega Liters
Barrels (42 gal)
Cubic Meters
Cubic Meters x 1000
Cubic Feet
Cubic Feet x 100
Cubic Feet x 1000
Second Foot Day
Million Cubic Feet
Acre Feet
Acre Inches
Imperial Gallons
Imperial Gallons
x 1000
Million Imperial
Gallons
Fluid Ounces
Bidirectional
1
Forward Total, Reverse Total, Net Total, Batch Forward Total, Batch Reverse Total
3
Power DC Power 9-36 Vdc @ 250 mA max, 30 mA average
Battery Backup
(Not for use as primary power)
DC powered units: One lithium 7.2V ‘D’ size battery pack, replaceable.
AC powered units: One 9V alkaline battery, replaceable.
AC Power 85-264Vac, 50/60Hz, 0.12A (iMAG4700rand4700ponly)
Scaled Pulse
Output
Signal Current sinking pulse, isolated, 36 Vdc at 10 mA max
Pulse Rates User-scalable from 0.1 to 99,999.9 volume units/pulse. Pulse width is one-half of pulse period with
minimum pulse width of 2.5 ms, 200 pulses/sec max. For battery option meters, pulse width varies with
frequency, 150 pulses/sec max.
Options 4-20mA Current Loop Isolated, passive, 24Vdc, 650 Ω maximum current loop
Serial Communications Isolated, asynchronous serial RS485, Modbus® RTU protocol
Sensus Smart Output Connects to Sensus SmartPoint
Cable Power/Output Cable 20ft (6m) standard length polyurethane jacketed cable—for power and outputs (lengths up to 200’
available).
Remote Display Cable 20ft (6m) standard length polyurethane jacketed cable—for connection between meter and remote
display (lengths up to 200’ available). (iMAG4700r)
Conductivity >20 microSiemens/cm
Empty Pipe Detection Hardware/software, conductivity-based
Regulatory
(EN 61326), certied to NSF/ANSI standard 61 60°C (140°F), CSA/CUS
Environmental NEMA 6P, IP68 (10ft (3m) depth, continuously)