6.2 Parameter explanations
INFORMATION ->
The information menu contains read-only parameters.
Speed Monitored/calculated current beltspeed in m/s
Load Current Net load on weighing unit or load cell in kg.
Note! This value is dependent of any entered compensation value of parameter “Angle”.
mV/V Calculated input mV/V signal from load cell (gross load).
mA Out Current output signal (analog mA).
Tare Zero (tare) shift changes since last system tare out “SysZERO” was executed.
TotPart The remaining weight that was not enough for increment of one totalising unit (in %),
for totaliser “Total". This value will be set to 0 when the totaliser is zeroset.
Sub1Part The remaining weight that was not enough for increment of one totalising unit (in %),
for totaliser “Sub1Tot". This value will be set to 0 when the totaliser is zeroset.
Sub2Part The remaining weight that was not enough for increment of one totalising unit (in %),
for totaliser “Sub2Tot". This value will be set to 0 when the totaliser is zeroset.
Serial# Serial no. of hardware pc-board.
System Firmware model information.
Prog.date Firmware revision date.
SYSTEM DATA ->
The system data menu contains system read/write parameters that can be altered as desired.
Angle The angle of inclination of the conveyor (from the horizontal plane).
This value may be changed at any time. NOTE! changing of this value will immedately affect
parameter “Load” and resulting flow rate indication
Max value: 35 degrees.
Default value: 0
TopDisp= Selection of desired upper row display indication.
- Flow
- Total
- Sub1Tot
- Sub2Tot
Default setting: Flow
BkLight= LCD display background light selection.
- Yes
-No
Default setting: Yes
The parameters “LoadLev”, “FlowLev” and “Spd.Lev” control the function and operation of output relay no.2.
Only one function can be designated to the relay.
At initial start-up, the default setting will be “0” to all 3 functions, which enables the function “Belt running” to relay
no.2.
18-08-16 S44-H15E 6-2
S-E-G SYSTEM A2-H15 INSTRUCTION