Pickup Setting I
[In]
I
[In]
Average Measured Trip Times [ms]
1-phase 3-phase
3.0 74 29
3.5 64 27
4.0 55 26
4.5 50 24
5.0 48 16
222 WIC1 WIC1-1.0-EN-MAN
9 Technical Data
9.2.2 Measured Trip Times (fN = 50 Hz, 1‑/3‑phase)