Take, with the syringe (that comes with the tightness test kit), 100 ml of
gas.
If the volume measuring procedure of the system ends correctly,
CHEMIST 600 automatically displays the measured volume, otherwise it
requires another test.
Starts the tightness
test after
measuring the
volume (SEE
SECTION 13.8.2).
V+
Adds up the volume of the
section of piping entered.
15/01/14
10:00
UNI 7129
Measure volume
Connect hose to P+
Press OK to start
System stabilization
Aspirate 100 ml of gas
Measure volume
Volume
dm
3
25
15/01/14
10:00
UNI 7129
Configuration
Stabilization
min
1
Print
auto
Fuel
L.P.G.
Test gas
air
Type test
full
Volume
dm
3
25.0
Measure volume
Calculate volume
OK
OK
15/01/14
10:00
UNI 7129
Configuration
Stabilization
min
1
Print
auto
Fuel
L.P.G.
Test gas
Air
Type test
completa
Volume
dm
3
18.0
Measure volume
Calculate volume
OK
15/01/14
10:00
UNI 7129
Calculate volume
V-
Material
Steel
Diameter
in
3/8"
Lenght
m
10.0
Zero volume
Volume
18.0
dm
3
Partial
1.2
dm
3
V+
Sets the material of the section of piping.
Sets the nominal diameter of the section of piping.
Sets the length of the section of piping.
Zeroes the volume previously acquired.
Total volume acquired.
Volume of the section of piping set below.