151
K600000000SE 030804 011018
15/01/14
10:00
Draft
Ambient CO
Pressure
Smoke
Temperature
Tightness test
Measurements
Leak detector Aux Meas.
04/03/16
10:00
Print
Report
Test
Header
Configuration
Printer
Measures list
PARAMETERS TO SET BEFORE
PROCEEDING (SEE SECTION 12.0):
Configuration
Header
Measures list
ACQUIRE THE FOLLOWING
MEASUREMENTS BEFORE
PROCEEDING WITH THE COMBUSTION
ANALYSIS (SE SECTION 13.0):
Draft
Smoke
Ambient CO
Temperature
Pressure
In you don’t, the measurements
will not be printed with the
combustion analysis.
15/01/14
10:00
ηs
%
91.4
Qs
%
8.6
ΔT
°C
74.7
T air
°C
15.4
T flue
°C
190.1
λ,n
1.25
CO
2
%
9.3
O
2
%
4.2
Combustion analysis
PRESS THE KEY ' ':
It starts saving the current analysis
according to the set mode.
- Manual See section 14.3
- UNI 10389 See section 14.4
- BImSchV See section 14.5
- data logger See section 14.6
PRESS THE KEY ' ':
It starts the printing on paper print-out of
the current analysis; additional
measurements are also printed, if they
are present in the memory.