508.366.1488 | www.semshred.com
25
Figure 21. Inside Stage 2 cutting chamber access door
3. Using a ¾” socket wrench, remove the two painted side bolts that hold the cutting chamber drawer in
place. See Figure 22.
NOTE: Never operate the unit without these bolts in place.
Figure 22. Two painted side bolts to remove
4. Unlatch the four latches holding the mid-hopper adapter to the bottom of Stage 1 (Figure 23). There are
two latches in the front and two in the back.