28
Using the HE 1 | Switching the tube headphone amplier on
Deactivating the blockage protection
If, during initialization, the operating elements and the amplier tubes cannot
extend automatically because they are blocked or if the glass cover cannot
open because it is blocked, the blockage protection will be activated. The
status LED ashes red. In this case, the HE 1 cannot be used.
To deactivate the blockage protection of the HE 1:
▷ Set the power switch to OFF to switch the HE 1 off and wait until the status
LED goes off (up to 30 seconds).
▷ Make sure that the operating elements, the amplier tubes and the glass
cover are not blocked.
▷ Set the power switch to ON to switch the HE 1 on again.
It might be that the operating elements retract to the “off” position.
▷ Press the on/off button.
The HE 1 switches on normally (see previous page).