eMotion in-depth guide
Manual control mode: Selects between Full Manual control and Assisted
Manual control when the remote control is turned on⁴².
Default value: Full Manual control
Security actions: The next checkboxes are used to disable certain Security
actions⁴³.
Ignore RC signals: Checking this option will result in the drone ignoring
any signals coming from a remote control (RC) transmitter on the ground.
Default value: unchecked
Caution: In certain regions it is illegal to disable the remote con-
trol connection between the drone and the operator on the ground.
Please check the laws in your region before enabling this option.
Return to Home in case of strong wind: Checking this box will enable the
Security action related to high wind strength (return to Home waypoint).
Un-checking this box will disable the Security action, however the drone
will continue to estimate the wind strength and direction and the In-flight
warning will continue to appear.
Default value: checked
Caution: The eBee RTK is not designed to fly in winds above 12 m/s.
Flying in high-wind conditions increases the chances of a crash that
may damage the drone and is done at your own risk.
Return to Home in case of poor GPS/GLONASS coverage: Checking this
box will enable the Security action (return to Home waypoint) related to
poor GPS/GLONASS signal coverage. Un-checking this box will disable the
Security action, however the In-flight warning will continue to appear.
Default value: checked
⁴² see section ‘Manual control of the eBee RTK on page 140 for more information
⁴³ see section ‘In-flight warnings’ on page 163 for more information on Security actions related to
specific In-flight warnings