Troubleshooting
10.2 Take-off vetoes
After successfully completing pre-flight checks the status LED becomes a solid
green to indicate that the drone is ready for take-off. At this point the eBee RTK
continuesto monitor its sensors and battery level. Ifat any pointthe drone detects
a condition that prevents it from beginning the automatic take-off procedure it
displays a Take-off veto in eMotion and the status LED changes to a blue pulse.
Once the Take-off veto is cleared the status LED returns to a solid green colour to
indicate that the drone is ready for take-off.
Table 4 on the next page presents all the Take-off vetoes that may occur and pos-
sible actions to remove the veto. If a veto persists after performing the suggested
action, we recommend you report the problem by following the instructions in
section ‘Reporting a problem with your eBee RTK on page 181.