Pitot malfunction A high airspeed was detected while on the ground.
User action: Be sure to protect the drone from the
wind and re-connect the battery. If the problem per-
sists, perform Check 4 in section ‘Full airframe and
sensor inspection’ on page 151. If this does not solve
the problem contact your eBee RTK reseller.
High current A too high current was detected, which may be
caused by an internal problem.
User action: Re-connect the battery. If the problem
occurs twice, contact your eBee RTK reseller.
Magnetometer
malfunction
There is an error with the drones magnetic field sen-
sor.
User action: Re-connect the battery. If the problem
persists, contact your eBee RTK reseller.
EEPROM
malfunction
There is an error with the memory chip of the drones
autopilot.
User action: Re-connect the battery. If the problem
persists, contact your eBee RTK reseller.
Barometer
malfunction
There is an error with the drones barometer.
User action: Be sure to place the drone on a flat
surface, reconnect the battery and do not move the
drone until pre-flight checks are complete. If the
problem persists, perform Check 3 in section ‘Full air-
frame and sensor inspection’ on page 151. If this
does not solve the problem contact your eBee RTK re-
seller.