SOHO Power Supply
47
State
Indication
Type
Specification
to operate again.
W18 M_Brk_not_Op
Motor Brake
not open
When motor brake is used, this warning tells that the
condition for opening the motor brake is not qualified.
In this case, the speed is not accelerated.
W19 Ext_Fault
External Fault
This tells that inverter gets the external fault signal when
it is stopped.
W20 Acc/Dec_Byp
V/F
Accel/Decel
Bypass Error
Acceleration and deceleration time can be prohibited
when V/F control is used. Over-Current Fault can be
caused. If [17] Accel/Decel Bypass, the terminal function,
is used and V/F control is used, this warning can be
generated. In V/F control, If frequency is changed
without Accel or Decel slop, the over-current can occur.
W21 Low_OV_Limit
Over Voltage
Limit
When there is a setting error in OV limit value.
W22 Sync_Com_Err
Synchronous
Com. Err
When there is an error in synchronous
communication.
W23 Slave Error
Slave Error
When there is an error from slaves.
*)W24 Line_Seq_Err
Line Sequence
Err
Line sequence error of VDC PWM converter
*)W25 Line_UV
Line Under
Voltage
When there is Under Voltage.
*)W26
Line_Disconnection
Line
Unbalance
When there is Unbalance input.
*)W27
Line Over-Voltage
Line
Connection
Test No
Fulfillment
When there is test No fulfillment.
W28 Line Unbalance
W29 Line_Connection
Check
W30 Profibus Error
W31 UV Limiting
W32 OV Limiting
W33 OC Limiting
W34 OT Limiting
W35 Warning Logic 1
W36 Warning Logic 2
W37 Warning Logic 3