Do you have a question about the Sequoia LISST-200X and is the answer not in the manual?
| Model | LISST-200X |
|---|---|
| Measurement Principle | Laser diffraction |
| Number of Size Classes | 32 |
| Measurement Rate | 1 Hz |
| Path Length | 5 cm |
| Weight in Water | 1.5 kg |
| Light Source | Laser diode, 670 nm |
| Data Output | RS-232 |
| Operating Temperature | -5 to 45 °C |
| Storage Temperature | -20 to 60 °C |
| Power Consumption | 5 W |
Explains laser diffraction principles and how the LISST-200X measures particle size.
Provides an overview of the LISST-200X's capabilities, components, and operation.
Step-by-step guide for initial setup, software installation, and data acquisition.
Detailed instructions for installation, communication, and configuration.
Instructions for installing the LISST-SOP software on a PC.
Guide to connecting the LISST-200X to the computer and establishing communication.
Procedures for acquiring and validating clean water background measurements for accurate data.
Steps to set up sampling parameters, operating modes, and start/stop conditions.
How to use and maintain the small external battery pack for short-term deployments.
Instructions for using the large external battery pack for long-term deployments.
Procedures for transferring and managing data files stored on the instrument.
Guide to processing raw data files (.RBN) into particle size distributions using LISST-SOP.
Method for processing multiple raw data files simultaneously.
How to view processed particle size distribution data and related parameters.
Essential checks for Laser Reference and Transmission values to ensure data validity.
Procedure for acquiring, displaying, and storing data in real-time.
How to connect and collect data from external analog sensors.
Setting up the LISST-200X to function as an auxiliary sensor for a CTD.
Details on data transmission via USB and RS-232, including terminal window usage.
How to open and use the terminal window for direct instrument interaction.
Summary of commands for display, setup, and acquisition/action.
Summary of commands for viewing instrument status and configuration.
Commands for configuring instrument settings like operating mode and start/stop conditions.
Commands for managing data collection, file operations, and instrument states.
Information on ensuring correct optical alignment for optimal instrument performance.
Explains the critical role of background measurements for accurate data.
Detailed technical specifications of the LISST-200X instrument.
Defines the 36 size ranges used for particle size distribution analysis.
Describes the various file types and extensions used by the LISST-SOP200X software.
Matlab functions for processing LISST-200X data.
Detailed wiring diagrams for the instrument's underwater connectors.
Explanations of the buttons and icons within the LISST-SOP software.
Discusses the models used for particle shape inversion in data processing.
Common issues and solutions related to data offloading and instrument querying.
Details the limited extended warranty provided by Sequoia Scientific.