Before Calling for Service Section 5
5-2
Part Number 020005256 5/15
Pump Troubleshooting
Problem Possible Cause Corrective Action
Pump motor does not
shut off
Problem with probe or probe harness.
Pump motor
intermittent
Problem with probe or probe harness
Pump motor does not
pump
Water pressure from water source is not
high enough
Verify water pressure leading into pump inlet is 40 psi
minimum.
1. Remove probe electronics.
2. Pass magnetic tip of screwdriver by
lower end of tube extending from
electronics package.
3. Reed switch will close.
4. Carbonator operates.