6
Electrical installation
Electrical connections
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
110
Phase reversal cable
INFORMATION
If you are using an encoder, note that you also need an encoder signal reversal cable
in addition to the phase reversal cable. For more information about encoder signal re-
versal cables, refer to the description of the encoder connection.
11kW device power IEC/UL
Cable Length/installation
type
Type Wiring diagram
Part number: 18119638
Cable design: 4G6
Han
®
10B↔Han
®
10B
Fixed length
D/6.0
U1 – V1
V1 – U1
W1 – W1
13 – 13
14 – 14
15 – 15
TF+ – TF+
TF-–TF-
15kW device power IEC/UL
Cable Length/installation
type
Type Wiring diagram
Part number: 18113745
Cable design: 4G10
Han
®
10B↔Han
®
10B
Fixed length
D/10.0
U1 – V1
V1 – U1
W1 – W1
13 – 13
14 – 14
15 – 15
TF+ – TF+
TF-–TF-
26596598/EN – 10/2020