10.11 Safety technology
10.11.1 General
Safety characteristics
Approved safety classes of
the device
Performance level d according to ENISO13849‑1
Service life 20 years
Safe condition Frequency inverter does not generate a rotating field. Connected brakes
are de-energized.
Probability of dangerous fail-
ure per hour (PFH value)
0 FIT (fault exclusion)
10.11.2 Interfaces for safe disconnection
X5502
Size Size1 Size2
Performance class 2.2kW/4.0kW/7.5kW 11kW/15kW/22kW
Control voltage range for a
safe state
DC0V–4V
Maximum permitted residual
current in safe state
DC6mA
Control voltage range for a
non-safe state
DC4V–28.8V
Rated output current DC500mA
Output current limit Max. DC2A (until thermal switch-off)
Power consumption of single
drive
3.7W 8.7W
Input capacitance of single
drive (diode-decoupled)
32µF 275µF
Power consumption of group
drive
4.9W 9.9W
Input capacitance of group
drive (diode-decoupled)
37µF 280µF
26596598/EN – 10/2020