10
Technical data
Communication and control unit
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
171
10.10.2 DC24V output
DC24V output X2312
Nominal output voltage DC24V
Nominal output current DC 500mA
Output current limit Maximum 1.4A
10.10.3 Ethernet fieldbus interface
Ethernet fieldbus interface X4233
Transmission rate 10/100Mbit/s
Properties Half/full duplex, auto negation, auto crossover
Maximum cable length 100m according to IEEE 802.3
10.10.4 CAN interfaces
CAN interfaces X4101/X4111
General According to CAN specification 2.9, parts A and B
Transmission technology according to ISO11898
A maximum of 64 stations
Baud rate 125kBaud–1MBaud
Maximum cable length Depends on the baud rate according to CAN specification
Bus termination
X4111
X4101
120Ohm terminated in the device
No integrated terminating resistor
10.10.5 RS485 interface
RS485 interface X4011
General I/O standard
Baud rate 2.4–115.2 kBaud
Bus termination The interface is equipped with a dynamic terminating resistor inside the
device.
26596598/EN – 10/2020