5.2 Mounting position
INFORMATION
When using the horizontal mounting position [3], power is reduced by 50% because
of reduced heat convection.
The following figure shows permitted and not permitted mounting positions:
27021598964695435
[1] Permitted vertical mounting position
[2] Mounting positions that are not permitted
[3] Conditionally permitted horizontal mounting position
5.3 Minimum clearance
INFORMATION
• Observe the following minimum clearances during installation:
– For connection of the cables and plug connectors
– For handling the display, diagnostics and operating elements
– For heat convection at the cooling fins if the device has cooling fins
• For more information on the required minimum clearances, refer to the dimension
drawings in chapter "Technical data"(→2164).