6.12.16 X3222: Multi-distance encoder
Function
Connection for HIPERFACE
®
,SSI, sin/cos,TTL,HTL and RS422 encoders
Connection type
M23, insulator, P part, 12-pin, female, +20°-coded
Wiring diagram
No. Name Function
1 CLK (C) Clock line(Signal track C (K0))
2 /CLK (/C) Negated clock line(Negated signal track C (/K0))
3 A Signal track A (K1)
4 /A Negated signal track A (/K1)
5 B Signal track B (K2)
6 /B Negated signal track B (/K2)
7 Data- Data line (-)
8 Data+ Data line (+)
9 GND Reference potential
10 +24V DC 24 V output
Total current load of DC 24V encoder supply
≤400mA
11 GND Reference potential
12 +12V DC 12V output
Total current load of DC 12V encoder supply
≤650mA
26596598/EN – 10/2020