EasyManua.ls Logo

SEW-Eurodrive MOVIPRO PHC21A-A075M1-E45C-C5 - Shutdown

SEW-Eurodrive MOVIPRO PHC21A-A075M1-E45C-C5
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
Service
Shutdown
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
162
9.7 Shutdown
WARNING
Electric shock due to charged capacitors.
Severe or fatal injuries.
Observe a minimum switch-off time after disconnecting the supply voltage:
10minutes.
To shut down the device, disconnect it from the power supply using appropriate mea-
sures.
9.8 Storage
Observe the following instructions when shutting down or storing the device:
Cover the connections with the supplied protection caps.
Place the device on a side without connectors.
Ensure that the device is not subject to mechanical impact.
Observe the notes on storage temperature in chapter "Technical data"(→2164).
9.9 Extended storage
Electrolytic capacitors are used in the frequency inverters. They are subject to aging
effects when de-energized. If the device is connected to the voltage supply directly
after a long storage period, the capacitors can be damaged.
In case of extended storage, connect the device to the supply voltage for at least 5
minutes every 2 years. Otherwise, the service life of the device may be reduced.
If you have not performed maintenance regularly every 2 years, SEW‑EURODRIVE
recommends that you increase the supply voltage slowly up to the maximum voltage.
This can be done, for example, by using a variable transformer for which the output
voltage has been set according to the following overview:
Step 1: AC 0V to AC 350V within a few seconds
Step 2: AC 350V for 15 minutes
Step 3: AC 420V for 15 minutes
Step 4: AC 500V for 1 hour
26596598/EN – 10/2020