6
Electrical installation
Connection block
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
67
The connection designation of the device is specified on the connection block label on
the device cover. Make sure that the latches of the connections engage after you
plugged the plug connector into the connections.
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[12]
[11]
[D]
[C]
[C]
[13]
[B]
[A]
[E]
9007231966375051
[A] → DC 24 V output connection
[B] → Socket for encoder option connection
[C] → Motor output connection
[D] → Braking resistor connection
[E] → Supply connection
[1] X4101_11 CAN bus – system bus
[2] X4101_12 CAN bus – system bus
[3] X4111 CAN bus – external
[4] X4011 RS485 interface – external
[5] X2312 DC 24V output to supply external components
[6] X4233_12 Ethernet fieldbus
[7] X4233_11 Ethernet fieldbus
[8] X4223 Ethernet service interface (4-pin)
[9] X4235 Ethernet service interface
[10] X5001 Digital inputs/outputs – communication and control unit
[11] X5502 Safe disconnection – input
[12] X4401 ID module
[13] X5111 Fan subassembly, only for devices of size2
26596598/EN – 10/2020