6.12.5 X1214: AC 400V input/DC 24V supply for supply cable
Function
• AC 400V input to supply devices up to 22kW
• Output and input for DC24V
• Signal contact for external maintenance switch
• For connecting the connection cable
Connection type
Han-Modular
®
10 B, male, 1 locking latch
Wiring diagram
ca
8
12 156 2 156 2
47 38 47 33
[a] Han
®
C module, male
No. Name Function
1 L1 Supply system phase 1
2 L2 Supply system phase 2
3 L3 Supply system phase 3
[b] Han
®
EE module, male
Coding of the device power, see chapter "Coding"(→280)
[c] Han
®
EE module, male
No. Name Function
1 +24V_C DC24V input – backup voltage
2 SC Signal contact for maintenance switch
3 VO24 DC 24 V output
4 n.c. Not connected
5 0V24_C 0V24 reference potential – backup voltage
6 n.c. Not connected
7 GND Reference potential
8 n.c. Not connected