6
Electrical installation
Electrical connections
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
87
6.12.6 X2012: Motor with brake control
INFORMATION
To avoid damage or malfunction of the drive system, do not use motors with built-in
brake rectifier in conjunction with this product.
Function
Power connection for motor with brake up to 7.5kW
Connection type
Han-Modular
®
6B, female, 1 locking latch
Connection diagram
[A] Han
®
Cmodule, female
No. Name Function
1 U Motor phase U output
2 V Motor phase V output
3 W Motor phase W output
[B] Han
®
Eprotectedmodule, female
No. Name Function
1 TF/TH/KTY+ Motor temperature sensor (+)
2 15 Brake terminal 15 (blue)
3 13 Brake terminal 13 (red)
4 14 Brake terminal 14 (white)
5 n.c. Not connected
6 TF/TH/KTY- Motor temperature sensor (-)
Hinged frame
No. Name Function
– PE PE connection
26596598/EN – 10/2020