6
Electrical installation
Electrical connections
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
97
Phase reversal cable
INFORMATION
If you are using an encoder, note that you also need an encoder signal reversal cable
in addition to the phase reversal cable. For more information about encoder signal re-
versal cables, refer to the description of the encoder connection.
2.2kW/4kW device power IEC/UL
Cable Length/installation
type
Type Wiring diagram
Part number: 18113737
Cable design: 4G2.5
Han
®
6B↔Han
®
6B
Fixed length
D/2.5
U1–V1
V1–U1
W1–W1
13–13
14–14
15–15
TF+–TF+
TF-–TF-
7.5 kW device power IEC
Cable Length/installation
type
Type Wiring diagram
Part number: 18113737
Cable design: 4G2.5
Han
®
6B↔Han
®
6B
Fixed length
D/2.5
U1–V1
V1–U1
W1–W1
13–13
14–14
15–15
TF+–TF+
TF-–TF-