Technical data
Input voltage ranges
Operating Instructions – MOVITRAC
®
LTP-B
191
10.4 Input voltage ranges
Depending on the model, the inverters are designed for direct connection to the follow-
ing voltage sources:
MOVITRAC
®
LTP-B
Nominal voltage ac-
cording to EN50160
Power rating Connection
type
Rated frequency
200 – 240 V ± 10% 0.75 – 2.2 kW 1-phase* 50–60Hz±5%
200 – 240 V ± 10% 0.75 – 75kW 3-phase
380–480V±10% 0.75 – 160kW
500 – 600V ± 10% 0.75 – 110kW
Units that are connected to a 3-phase supply system are designed for a maximum
power grid imbalance of 3% between the phases. For supply systems with a power
grid imbalance of more than 3% (for example, in India and parts of the Asia-Pacific re-
gion including China), SEW-EURODRIVE recommends that you use input chokes.
INFORMATION
*Single-phase inverters can also be connected to 2 phases of a 3-phase supply sys-
tem of 200–240V.
25813137/EN – 08/2018

Table of Contents

Other manuals for SEW-Eurodrive MOVITRAC LTP-B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SEW-Eurodrive MOVITRAC LTP-B and is the answer not in the manual?

SEW-Eurodrive MOVITRAC LTP-B Specifications

General IconGeneral
BrandSEW-Eurodrive
ModelMOVITRAC LTP-B
CategoryDC Drives
LanguageEnglish

Related product manuals