AR-M256/M257/M258/M316/M317/M318/5625/5631 SIMULATION 8 - 12
Note: In SIM 7-1, pressing [CA] key terminates the simulation and the
machine enters the aging mode without resetting. Therefore, to
perform “4. Intermittent setup,” the intermittent cycle must be set
with SIM 7-6 in advance.
Reset is not performed when the machine enters the aging mode.
Operation/procedure
1. Enter the interval aging cycle time (sec) with the 10-key pad.
Refer to SIM 7-1.
2. Press the [START] key.
When the [START] key is pressed in aging, copying is performed con-
tinuously. This simulation is used to set the time interval between copy
operations in the unit of second.
This setting is valid when SIM 7-1 (Intermittent setting) is enabled.
Operation/procedure
1. Warm-up starts by the cover open/close.
(Can be performed repeatedly by open/close of the cover.)
2. The warm-up time is counted up and displayed in the unit of sec.
If the [CA] key is pressed at this time, count-up is interrupted to ter-
minate the simulation. (However, warm-up is continued.)
3. After completion of warming up, “WARM UP COMPLETED” is dis-
played and the control returns to the initial screen.
Operation/procedure
1. Touch the exposure mode to be changed.
The current set value is displayed.
2. Enter the set value with the 10-key.
3. Press the [START] key.
Output is made with the entered value, and the display returns to the
original state.
(
∗) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
The minimum increment is 5V.
The result of (Set value) / 5 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *5)
is used as the set value.
Therefore, a multiple number of 5 must be entered. If not, the value +1
to +4 is displayed after pressing [START] key.
7-6
Purpose Setting/Operation test/check
Function (Purpose) Used to set the cycle of intermittent aging.
Item Operation
Setting range 1-255
Default 3
7-8
Purpose Setting/Operation test/check
Function
(Purpose)
Used to set the display of the warm-up time.
Item Operation
8
8-1
Purpose Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the
developing bias voltage in each copy mode and the
control circuit.
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Developer/Toner hopper
Item Content
Setting
range
Default
1 AE (145) AE (145mm/s)
200-
650
450
2 TEXT (145) Character (145mm/s) 500
3 TEXT/PHOTO (145)
Character/Photo
(145mm/s)
500
4 PHOTO (145) Photo (145mm/s) 500
5 TONER SAVE (145) Toner save (145mm/s) 400
6 AE (122) AE (122mm/s) 400
7 TEXT (122) Character (122mm/s) 450
8 TEXT/PHOTO (122)
Character/Photo
(122mm/s)
450
9 PHOTO (122) Photo (122mm/s) 450
10 TONER SAVE (122) Toner save (122mm/s) 376
SIMULATION 8-1
426
1/1
DV BIAS COPY SETTING. INPUT VALUE 200-550, AND PRESS
START.
1: AE 426
2: TEXT 450
3: TEXT/PHOTO 450
4: PHOTO 450
5: SUPER/PHOTO 400
6: TONER SAVE 376
SIMULATION 8-1