Loading...
UX-40DE
FO-50DE
DTMF detection time 50ms 80ms 100ms 120ms
1 No. 100110
2 No. 201010
3 Protection of remote reception(5 )Yes No 0
detection
4 Remote reception with GE telephone Compatible Not compatible 1
5 Remote operation code figure by external Binary input 0 OPTION
6 TEL (0~9) No. = 8 4 2 1 1
7 5 6 7 8 0
8 0 1 0 1 1
1 CNG detection in STAND-BY mode Yes No 1 OPTION
Number of CNG detect(AM mode) 1 pulse 2 pulses 3 pulses 4 pulses
2 No. 200110
3 No. 301011
Number of CNG detect(STAND-BY mode) 1 pulse 2 pulses 3 pulses 4 pulses
4 No. 400110
5 No. 501011
6 Reserved 0
7 Reserved 0
8 Reserved 0
1 Quiet detect time Binary input 0 OPTION
2 (0~15sec setting by 1sec step) No. = 8 4 2 1 1
3 1 2 3 4 1
4 0 1 1 0 0
5 Quiet detect start timing Binary input 0 OPTION
6 (0~15sec setting by 1sec step) No. = 8 4 2 1 0
7 5 6 7 8 0
8 0 0 0 0 0
1 Reserved 0
2 Reserved 0
3 Reserved 0
4 Reserved 0
5 Reserved 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
OGM detect timer Not work 100ms 200ms 300ms
1 No. 100110
2 No. 201011
Section time of quiet detection 30s 40s 50s 60s
3 No. 300110
4 No. 401011
5 Reserved 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
1 Quiet detect level setting Binary input 1
2 (0~-44dBm setting by 1dBm step) No. = 32 16 8 4 2 1 0
3 1 2 3 4 5 6 1
4 1 0 1 1 0 0 1
5 0
6 0
7 Fax switching when A.M. full Yes No 0 OPTION
8 Reserved 0
SW
NO.
DATA
NO.
ITEM
Switch setting and function
1
0
2 – 9
SW
l
F1
SW
l
F2
SW
l
G1
SW
l
G2
SW
l
G3
SW
l
G4
Remarks
Initial
setting

Other manuals for Sharp UX-40