Emphasizes manual reading for safe operation and to prevent impairment of safety features.
Outlines basic safety precautions, national laws, regulations, and local ordinances for unit use.
Provides contact details for customer support, including phone, email, and mailing address.
Explains requirements for CO2 supply, quality, pressure, and dual-stage regulator.
Lists standards for temperature and CO2 reference devices needed for calibration.
Instructions for checking the unit and accessories for concealed loss or damage upon delivery.
Diagram identifying key components, ports, and features on the incubator's exterior.
Guide to record model, serial, and part numbers from the data plate for future reference.
A comprehensive checklist for installing the incubator in a new workspace location.
Specifies optimal room temperature, humidity, and environmental factors for incubator performance.
Defines voltage, amperage, grounding, circuit breaker, and power cord specifications for safe operation.
Provides essential guidelines and precautions for safely lifting and moving the heavy incubator unit.
Step-by-step instructions for installing the HEPA filter and air duct inside the incubation chamber.
Procedure for connecting the incubator to single or dual CO2 gas supply sources.
Detailed steps for filling the water jacket with the correct amount of water for thermal insulation.
Details how to turn the incubator on and off using the main power switch.
Explains the graduated dial and red indicator light for the Over Temperature Limit safety cutoff.
Describes the current temperature display, setpoint adjustment buttons, and alarm indicators.
Explains the CO2 display, setpoint adjustment buttons, and CO2 injecting status indicator.
Explains how the incubator heats using PID control and its reliance on natural heat radiation for cooling.
Details passive humidification using the included pan and copper token for optimal chamber humidity.
Describes how the incubator controls CO2 concentration using an infrared sensor and PID control.
Step-by-step guide to prepare the incubator for normal use after installation.
Instructions for adjusting the temperature setpoint using the control panel's Up and Down buttons.
Instructions for setting the desired CO2 concentration percentage in the chamber.
Detailed procedure for setting the mechanical heating cutoff (OTL) for safety.
Recommendations for sample placement and spacing to ensure proper airflow and temperature uniformity.
Procedure for cleaning and disinfecting the incubator chamber and its removable interior components.
Detailed step-by-step instructions for removing and replacing the chamber HEPA filter.
Procedure to calibrate the incubator's temperature display using a calibrated temperature reference device.
Procedure to calibrate the incubator's CO2 display using a calibrated gas reference device.
Information on the water jacket anode's function and recommended water quality for protection.
Details the shipping and unit weight of the incubator in both pounds and kilograms.
Provides exterior and interior dimensions of the incubator in both inches and millimeters.
Specifies the CO2 concentration range, accuracy, and recovery time of the incubator.
Lists the incubator's temperature range, uniformity, and stability specifications.
Lists available optional accessories for the incubator, such as regulators and shelf kits.
Provides information on how to order replacement parts and accessories online or via phone.