Parameter No. 25 - Set timer units to s or ms for O (O1)
Set the timer units to seconds or milliseconds. Choose if you want to set the timer in seconds or
milliseconds in Parameters No. 19, 20.
Values size: 1 Byte
Default value: 0
Values & descriptions:
0 timer set in seconds
1 timer set in milliseconds
Parameter No. 91 - Water Alarm
This parameter determines which alarm frames the Device should respond to and how. The
parameters consist of 4 bytes, the three most significant bytes are set according to the official
Z-Wave protocol specification.
Values size: 4 Byte
Default value: 0
Values & descriptions:
0 no action
1 open relay
2 close relay
Parameter No. 92 - Smoke Alarm
This parameter determines which alarm frames the Device should respond to and how. The
parameters consist of 4 bytes, the three most significant bytes are set according to the official
Z-Wave protocol specification.
Values size: 4 Byte
Default value: 0
Values & descriptions:
0 no action
1 open relay
2 close relay